Write pending rate of the storage system to which the quorum disk is assigned

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

If the write-pending rate of a storage system to which the quorum disk (external volume) at the primary or secondary site is assigned is high, the I/O performance of the GAD pair volumes might decrease or the GAD pairs might be suspended by some failure.

To address this situation:

  1. Use Export Tool 2 on the primary or secondary storage system to perform regular monitoring of the write-pending rate of each storage system to which the quorum disks are assigned.
  2. If the write-pending rate exceeds 70%, review your configuration and consider the following actions:
    • Lower the I/O load in the storage system.
    • If the cache load is high:

      - Lower the I/O load.

    • The cache write pending rate might exceed 70% temporarily due to failures on the primary and secondary storage systems. To prevent the I/O performance of the GAD pair volumes from decreasing or the GAD pairs from being suspended by failures related to this situation, the write-pending rate should be below 35% for each storage system under normal conditions.