The following table lists the requirements and cautions that apply when you configure the system by using NVMe-oF for the connections between the host and the storage system. For more information about NVMe-oF, see the Provisioning Guide.
|
Item |
Requirements |
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Remote paths (when using NVMe-oF) |
The configuration in which NVMe-oF is used for a remote path is not supported. |
|||||||||||||||
|
Physical paths between the host and the storage system (when using NVMe-oF) |
For the timeout period for the commands between the host and the storage system, set a value that is equal to or greater than the timeout period for the commands between the storage systems. |
|||||||||||||||
|
Pair creation by using an NVMe-oF volume and a Fibre Channel or iSCSI volume with an LU path defined |
A pair that uses an NVMe-oF volume (on which a namespace on the NVM subsystem with an NVM subsystem port added is defined) and a Fibre Channel or iSCSI volume (with an LU path defined) cannot be created. The following table lists whether pair creation is available by combining a P-VOL and an S-VOL.
|
|||||||||||||||
|
Configuration that uses a volume connected to a host via NVMe-oF |
The following restrictions apply when a volume connected to a host via NVMe-oF is used as a volume of a GAD pair:
|
|||||||||||||||
|
Configuration that is used with Universal Replicator |
A GAD pair created by using a volume connected to a host via NVMe-oF cannot be used with Universal Replicator. |
|||||||||||||||
|
Pair operation by using CCI |
To use a volume connected to a host via NVMe-oF, specify a pair volume using a dummy LU. For more information, see the topic related to the pair operations on namespaces for NVMe-oF in the Command Control Interface User and Reference Guide. |