Direct connection

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04

You can connect two storage systems directly to each other.



You can use host mode option (HMO) 51 (Round Trip Set Up Option) to improve response time of host I/O between the storage systems for long-distance direct connections (up to 10 km longwave) when the open package is used.

Note: If you use iSCSI, the HMO settings are invalid.

For more information about HMOs, see the Provisioning Guide for your storage system.

The fabric and topology settings depend on the settings of the packages, the protocol used for the connection between the storage systems, and the setting of HMO 51. The link speed that can be specified differs for each condition.

Package name

Protocol

HMO 51 setting

Fabric setting

Topology: remote replication ports

Link speed that can be specified

CHB(FC32G)

32GbpsFC

OFF

OFF

FC-AL

  • 4 Gbps
  • 8 Gbps

ON

OFF

FC-AL

  • 4 Gbps
  • 8 Gbps

OFF

OFF

Point-to-Point

  • 16 Gbps
  • 32 Gbps

ON

OFF

Point-to-Point

  • 16 Gbps
  • 32 Gbps
CHB(FC64G) 64GbpsFC

OFF

OFF

Point-to-Point

  • 16 Gbps
  • 32 Gbps
  • 64 Gbps

ON

OFF

Point-to-Point

  • 16 Gbps
  • 32 Gbps
  • 64 Gbps