- Power on the storage system at the secondary site.
-
Confirm that the primary and secondary storage systems and the external storage system for the quorum disk do not have any blocked parts.
If any parts are blocked, recover them.
- Check for SIMs about path blockage, and complete the SIMs.
-
Confirm that the pair status of the P-VOLs of the GAD pairs is PSUS(Local) and that the pair status of the S-VOLs is SSUS(Block).
pairdisplay -g oraHA -fcxe -IH0
-
On the storage system at the primary site, resynchronize the GAD pairs by specifying the primary volume.
pairresync -g oraHA -IH0
-
Confirm that the pair status of the P-VOLs and S-VOLs of the GAD pairs has changed to PAIR (Mirror (RL)).
pairdisplay -g oraHA -fcxe -IH0
- Using the multi-path software, resume I/O from the servers to the storage system at the secondary site.