Powering on the secondary storage system

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23
  1. Power on the storage system at the secondary site.
  2. Confirm that the primary and secondary storage systems and the external storage system for the quorum disk do not have any blocked parts.

    If any parts are blocked, recover them.

  3. Check for SIMs about path blockage, and complete the SIMs.
  4. Confirm that the pair status of the P-VOLs of the GAD pairs is PSUS(Local) and that the pair status of the S-VOLs is SSUS(Block).
    pairdisplay -g oraHA -fcxe -IH0
  5. On the storage system at the primary site, resynchronize the GAD pairs by specifying the primary volume.
    pairresync -g oraHA -IH0
  6. Confirm that the pair status of the P-VOLs and S-VOLs of the GAD pairs has changed to PAIR (Mirror (RL)).
    pairdisplay -g oraHA -fcxe -IH0
  7. Using the multi-path software, resume I/O from the servers to the storage system at the secondary site.