  1. Power on the primary and secondary storage systems.
  2. Confirm that the primary and secondary storage systems and the external storage system for the quorum disks do not have any blocked parts.

    If any parts are blocked, recover them.

  3. Check for SIMs about path blockage, and complete the SIMs.
  4. Confirm that the pair status of the P-VOLs of the GAD pairs is PSUS(Local) and that the pair status of the S-VOLs is SSUS(Block).
    pairdisplay -g oraHA -fcxe -IH0
  5. On the primary storage system, resynchronize the GAD pairs by specifying the primary volume.
    pairresync -g oraHA -IH0
  6. Confirm that the pair status of the P-VOLs and S-VOLs of the GAD pairs has changed to PAIR (Mirror (RL)).
    pairdisplay -g oraHA -fcxe -IH0
  7. Resume I/O from the servers to the primary and secondary storage systems.