Use the following procedure to properly power on the external storage system with I/O at the secondary site.
- Power on the external storage system.
-
Confirm that the primary and secondary storage systems and the external storage systems for the quorum disks do not have any blocked parts.
If any parts are blocked, recover them.
- Check for SIMs about path blockage, and complete the SIMs.
-
On the primary and secondary storage systems, establish connections to the quorum disks.
raidcom check_ext_storage external_grp -ldev_id 0x8888 -IH1
-
Confirm that the external storage system is connected correctly.
raidcom get path -path_grp 1 -IH1 PHG GROUP STS CM IF MP# PORT WWN PR LUN PHS Serial# PRODUCT_ID LB PM 1 1-2 NML E D 0 CL5-C 50060e8007823521 1 0 NML 833333 VSP One B20 series N M -
On the primary and secondary storage systems, confirm that the connections to the quorum disks have been established.
raidcom get external_grp -external_grp_id 1-2 -IH1
-
Confirm that the external volumes of the primary and secondary storage systems are recognized as quorum disks.
raidcom get ldev -ldev_id 0x8888 -IH1
- Check for SIMs about quorum disk blockade at the primary and secondary sites, and complete the SIMs.