- Power on the external storage system.
-
Confirm that the primary and secondary storage systems and the external storage system for the quorum disk do not have any blocked parts.
If any parts are blocked, recover them.
- Check for SIMs about path blockage, and complete the SIMs.
-
On the primary and secondary storage systems, establish the connections to the quorum disks.
raidcom check_ext_storage external_grp -ldev_id 0x9999 -IH0
-
On the primary and secondary storage systems, confirm that the connections to the quorum disks have been established.
raidcom get external_grp -external_grp_id 1-1 -IH0
-
Confirm that the external volumes of the primary and secondary storage systems are recognized as quorum disks.
raidcom get ldev -ldev_id 0x9999 -IH0
- Check for SIMs about quorum disk blockade at the primary and secondary sites, and complete the SIMs.