Powering on the external storage system, I/O at primary site

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23
  1. Power on the external storage system.
  2. Confirm that the primary and secondary storage systems and the external storage system for the quorum disk do not have any blocked parts.

    If any parts are blocked, recover them.

  3. Check for SIMs about path blockage, and complete the SIMs.
  4. On the primary and secondary storage systems, establish the connections to the quorum disks.
    raidcom check_ext_storage external_grp -ldev_id 0x9999 -IH0
  5. On the primary and secondary storage systems, confirm that the connections to the quorum disks have been established.
    raidcom get external_grp -external_grp_id 1-1 -IH0
  6. Confirm that the external volumes of the primary and secondary storage systems are recognized as quorum disks.
    raidcom get ldev -ldev_id 0x9999 -IH0
  7. Check for SIMs about quorum disk blockade at the primary and secondary sites, and complete the SIMs.