Powering on the primary, secondary, and external storage systems

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04
  1. Power on the primary and secondary storage systems and the external storage system.
  2. Confirm that the primary and secondary storage systems and the external storage system for the quorum disks do not have any blocked parts.

    If any parts are blocked, recover them.

  3. Check for SIMs about path blockage, and complete the SIMs.
  4. On the primary and secondary storage systems, establish connections to the quorum disks.
    raidcom check_ext_storage external_grp -ldev_id 0x9999 -IH0
  5. On the primary and secondary storage systems, verify that the connections to the quorum disks have been established.
    raidcom get external_grp -external_grp_id 1-1 -IH0
  6. Confirm that the external volumes of the primary and secondary storage systems are recognized as quorum disks.
    raidcom get ldev -ldev_id 0x9999 -IH0
  7. Check for SIMs about quorum disk blockade at the primary and secondary sites, and complete the SIMs.
  8. Confirm that the pair status of the P-VOLs of the GAD pairs is PSUS(Local) and that the pair status of the S-VOLs is SSUS(Block).
    pairdisplay -g oraHA -fcxe -IH0
  9. Resynchronize the GAD pairs from the primary storage system by specifying the primary volume.
    pairresync -g oraHA -IH0
  10. Confirm that the pair status of the P-VOLs and S-VOLs of the GAD pairs has changed to PAIR (Mirror (RL)).
    pairdisplay -g oraHA -fcxe -IH0
  11. Using the multi-path software, resume I/O from the servers to the storage systems at the primary and secondary sites.