Relationship between GAD status, pair status, and I/O mode

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04

You should understand the relationship between the GAD status, pair status, and I/O mode to be informed about your GAD pairs.

The following table lists the GAD statuses and describes the relationship between the GAD status, pair status, and I/O mode. "N" indicates that pair status or I/O mode cannot be identified due to a failure in the storage system.

GAD status

When to suspend

P-VOL

S-VOL

Volume that has the latest data

Pair status

I/O mode

Pair status

I/O mode

Simplex

Not applicable

SMPL

Not applicable

SMPL

Not applicable

Not applicable

Mirroring

Not applicable

INIT

Mirror(RL)

INIT

Block

P-VOL

Not applicable

COPY

Mirror(RL)

COPY

Block

P-VOL

Mirrored

Not applicable

PAIR

Mirror(RL)

PAIR

Mirror(RL)

P-VOL and S-VOL

Quorum disk blocked or no quorum disk volume

Not applicable

PAIR

Mirror(RL)

PAIR

Mirror(RL)

P-VOL and S-VOL

Suspended

Pair operation

PSUS

Local

SSUS

Block

P-VOL

Failure

PSUE1

Local

PSUE

Block

P-VOL

PSUE1

Local

SMPL

Not applicable

P-VOL

PSUE1

Local

N

N

P-VOL

Pair operation

PSUS

Block

SSWS

Local

S-VOL

Failure

PSUE

Block

SSWS1

Local

S-VOL

SMPL

Not applicable

SSWS1

Local

S-VOL

N

N

SSWS1

Local

S-VOL

Blocked

Not applicable

PSUE

Block

PSUE

Block

P-VOL and S-VOL

Not applicable

PSUE

Block

N

N

P-VOL and S-VOL

Not applicable

N

N

PSUE

Block

P-VOL and S-VOL

Notes:

1. If the server does not issue the write I/O, the pair status might be PAIR, depending on the failure location.