You should understand the relationship between the GAD status, pair status, and I/O mode to be informed about your GAD pairs.
The following table lists the GAD statuses and describes the relationship between the GAD status, pair status, and I/O mode. "N" indicates that pair status or I/O mode cannot be identified due to a failure in the storage system.
|
GAD status |
When to suspend |
P-VOL |
S-VOL |
Volume that has the latest data |
||
|---|---|---|---|---|---|---|
|
Pair status |
I/O mode |
Pair status |
I/O mode |
|||
|
Simplex |
Not applicable |
SMPL |
Not applicable |
SMPL |
Not applicable |
Not applicable |
|
Mirroring |
Not applicable |
INIT |
Mirror(RL) |
INIT |
Block |
P-VOL |
|
Not applicable |
COPY |
Mirror(RL) |
COPY |
Block |
P-VOL |
|
|
Mirrored |
Not applicable |
PAIR |
Mirror(RL) |
PAIR |
Mirror(RL) |
P-VOL and S-VOL |
|
Quorum disk blocked or no quorum disk volume |
Not applicable |
PAIR |
Mirror(RL) |
PAIR |
Mirror(RL) |
P-VOL and S-VOL |
|
Suspended |
Pair operation |
PSUS |
Local |
SSUS |
Block |
P-VOL |
|
Failure |
PSUE1 |
Local |
PSUE |
Block |
P-VOL |
|
|
PSUE1 |
Local |
SMPL |
Not applicable |
P-VOL |
||
|
PSUE1 |
Local |
N |
N |
P-VOL |
||
|
Pair operation |
PSUS |
Block |
SSWS |
Local |
S-VOL |
|
|
Failure |
PSUE |
Block |
SSWS1 |
Local |
S-VOL |
|
|
SMPL |
Not applicable |
SSWS1 |
Local |
S-VOL |
||
|
N |
N |
SSWS1 |
Local |
S-VOL |
||
|
Blocked |
Not applicable |
PSUE |
Block |
PSUE |
Block |
P-VOL and S-VOL |
|
Not applicable |
PSUE |
Block |
N |
N |
P-VOL and S-VOL |
|
|
Not applicable |
N |
N |
PSUE |
Block |
P-VOL and S-VOL |
|
|
Notes: 1. If the server does not issue the write I/O, the
pair status might be PAIR, depending on the failure location.
|
||||||