The following table lists and describes the GAD suspend types displayed by the pairdisplay command in hexadecimal format.

CCI status

Suspend type

Volume

Description

0x03

Primary Volume by Operator

P-VOL

The user suspended the pair from the primary storage system. The S-VOL suspend type is "by MCU".

0x04

Secondary Volume by Operator

P-VOL

S-VOL

The user suspended the pair from the secondary storage system.

0x05

by MCU

S-VOL

The secondary storage system received a request from the primary storage system to suspend the pair. The P-VOL suspend type is Primary Volume by Operator or Secondary Volume by Operator.

0x06

by RCU

P-VOL

The primary storage system detected an error condition at the secondary storage system, which caused the primary storage system to suspend the pair. The S-VOL suspend type is Secondary Volume Failure.

0x08

Secondary Volume Failure

P-VOL

S-VOL

The primary storage system detected an error during communication with the secondary storage system, or an I/O error during update copy. In this case, the S-VOL suspend type is usually Secondary Volume Failure. This suspend type is also used when the number of paths falls below the minimum number of paths shown by the raidcom rcu command.

0x09

MCU IMPL

P-VOL

S-VOL

The primary storage system could not find valid control information in its nonvolatile memory during IMPL. This condition occurs only if the primary storage system is without power for more than 48 hours (that is, power failure and fully discharged backup batteries).

0x50

Initial Copy Failed

P-VOL

S-VOL

The pair was suspended before the initial copy operation was complete. The data on the S-VOL is not identical to the data on the P-VOL.