The following storage system configuration at the source UR primary site is used in the UR migration example.
Storage system
| Model | Serial number |
|---|---|
| VSP G700 | 411111 |
Primary volume
| Actual LDEV ID | Pool ID | Capacity | Port name | LU number |
|---|---|---|---|---|
| 11:11 | 0 | 500MB | CL1-C | 0 |
Journal volume
| Actual LDEV ID | Pool ID | Capacity |
|---|---|---|
| 88:81 | 1 | 30GB |
Ports to be used for remote connections
| Port name | Installation location of connected storage system |
|---|---|
| CL3-C | Source UR secondary site |
| CL4-C | Source UR secondary site |
| CL2-A | Target UR primary site |
| CL4-A | Target UR primary site |
Pairs
| Pair category | pair group name | Device name (LDEV ID) | Mirror ID |
|---|---|---|---|
| UR pair | oraUR00 | dev00 (11:11) | 1 |
| GAD pair | oraHA00 | dev10 (11:11) | 0 |