These are the recovery procedures for powering on the source UR primary storage
system on which the planned outage was performed "during migration". The procedure
for powering on the storage system on which the planned outage was performed "after
migration is complete" is the same as that for normal operations.
-
Power on the storage system at the source UR primary
site.
-
Verify that the UR primary and secondary storage systems do not have any blocked
parts.
If any parts are blocked, ask your service representative to
recover them.
-
On the storage system at the source UR secondary site, resynchronize (swap resync) the
UR pair
by specifying the S-VOL.
pairresync -g oraUR00 -swaps -IH2
When the command is
complete, the volume of the source
UR pair at the primary site has changed to the S-VOL
and the volume at the secondary site has changed to P-VOL.
-
Confirm that the pair status of each pair has changed as shown in the following
table.
| Pair type |
Pair status |
| P-VOL |
S-VOL |
| GAD pair |
PSUS(Local) |
SSUS(Block) |
| Source UR pair |
PAIR |
PAIR |
| Target UR pair |
- |
- |
| Legend: - : Any pair
status
|
-
Stop I/Os from the servers to the storage system at the source UR secondary
site.
-
On the storage system at the source UR primary site, suspend (swap suspend) the UR pair by
specifying the S-VOL.
pairsplit -g oraUR00 -RS -IH1
-
Start I/Os from the servers to the storage system at the source UR primary
site.
-
On the storage system at the source UR primary site, resynchronize (swap resync) the
UR pair
by specifying the S-VOL.
pairresync -g oraUR00 -swaps -IH1
-
Confirm that the source UR pair status has changed to PAIR.
-
Suspend the UR pair by specifying the P-VOL if the UR pair is
configured between the target sites.
-
On the storage system at the source UR primary site, resynchronize the GAD pairs.
-
Confirm that the pair status of each pair has changed as shown in the following
table.
| Pair type |
Pair status |
| P-VOL |
S-VOL |
| GAD pair |
PAIR(Mirror(RL)) |
PAIR(Mirror(RL)) |
| Source UR pair |
PAIR |
PAIR |
| Target UR pair* |
PSUS |
SSUS |
| * UR pair is configured between the target
sites. |
-
Resynchronize the UR pairs if the UR pair is configured between the target sites.
After powering on the storage system, continue the
UR environmental
migration operations by using GAD.