A source UR primary site failure that occurs after data migration is complete "during migration"
The table below shows the changes in the pair status before and after a failure.
| Pair type | Pair status before failure | Pair status after failure | ||
|---|---|---|---|---|
| P-VOL | S-VOL | P-VOL | S-VOL | |
| GAD pair | PAIR (Mirror (RL)) | PAIR (Mirror (RL)) | - (PSUE (Block) 2 ) | PAIR (Mirror (RL))3 |
| Source UR pair | PAIR | PAIR | - (PSUE 2 ) | PSUE 1,2 or PAIR 1 |
| Target UR pair4 | COPY or PAIR | COPY or PAIR | COPY or PAIR | COPY or PAIR |
Notes:
|
||||
When recovering from this failure, use the existing source UR environment for the system recovery. You must perform the pair operations so that the S-VOL at the source UR secondary site can accept I/Os from the server to continue the I/Os. After that, recover the primary site, and then restore the configuration using the S-VOL data.