Example of storage system configuration at the target GAD primary site

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

Storage system

Model Serial number Instance number
VSP One B85 944444 11

Device group

Target GAD Target UR Target UR delta resync
HA10 UR10 UR11

Journal

Journal group number Journal volume ID
10 0x9990 (Pool ID 1)

Quorum disk

Quorum ID for the temporary GAD pair for migration Quorum ID for the target GAD pair
20 10

Port

Port name Installation location of the connected storage system
CL2-A Source GAD primary site
CL4-A Source GAD primary site
CL1-C Target GAD secondary site
CL3-C Target GAD secondary site
CL5-C Target UR secondary site
CL7-C Target UR secondary site

Pair

Pair type Pair table name Device name (LDEV ID) Mirror ID
Target GAD pair HA10 dev100(01:00) 0
Temporary GAD pair for migration HA20 dev200(01:00) 3
Target UR pair UR10 dev110(01:00) 1