Recovering from a target GAD secondary site failure

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

The following procedure is for recovering from a system down failure of the storage system at the target GAD secondary site.

  1. If a temporary failure occurs at the target GAD secondary site, turn on the power of the storage system at the target GAD secondary site and then remove the cause of the failure.
    The pair status of the target GAD pair becomes PSUE(Local) for the P-VOL and PSUE(Block) for the S-VOL.

  2. Resynchronize the target GAD pair.
    Command example:
    pairresync -g HA10 -IH11

    In this configuration, the pair status of the target GAD pair does not change to PAIR and remains COPY.



  3. Continue the migration procedure.