Example of storage system configuration and configuration definition file at the target GAD secondary site

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

Storage system

Model Serial number
VSP One B24 844444

P-VOL used in a GAD pair in operation

Actual LDEV ID Pool ID Capacity Port name LU number
22:22 0 1 GB CL1-C 0

Port used for remote connection

Port name Usage
CL5-C Used in a target GAD pair
CL6-C

Pair

Pair category Pair group name Device name Mirror Quorum ID Usage
GAD pair oraHA02 dev02 (22:22) 2 2 Target GAD pair

horcm3.conf (target GAD secondary site)

HORCM_MONHORCM_MON
#ip_address service poll(10ms) timeout(10ms)
localhost 844444 -1 3000

HORCM_CMD
\\.\CMD-844444-8738

HORCM_LDEV
#GRP DEV SERIAL LDEV# MU#
oraHA02 dev3 844444 22:22 2

HORCM_INST
#GRP IP_ADR PORT#
oraHA02 localhost 833333