Example of storage system configuration and configuration definition file at the target GAD primary site

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04

Storage system

Model Serial number
VSP One B24 833333

P-VOL used in a GAD pair in operation

Actual LDEV ID Pool ID Capacity Port name LU number
11:11 0 1 GB CL1-C 0

Port used for remote connection

Port name Usage
CL3-C Used in a temporary GAD pair created for data migration
CL4-C
CL5-C Used in a target GAD pair
CL6-C

Pair

Pair category Pair group name Device name Mirror Quorum ID Usage
GAD pair oraHA01 dev01 (11:11) 1 1 Temporary GAD pair created for data migration
oraHA02 dev02 (11:11) 2 2 Target GAD pair

horcm2.conf (Target GAD primary site)

HORCM_MONHORCM_MON
#ip_address service poll(10ms) timeout(10ms)
localhost 833333 -1 3000

HORCM_CMD
\\.\CMD-833333-8738

HORCM_LDEV
#GRP DEV SERIAL LDEV# MU#
oraHA01 dev2 833333 11:11 1
oraHA02 dev3 833333 11:11 2

HORCM_INST
#GRP IP_ADR PORT#
oraHA01 localhost 411111
oraHA02 localhost 844444