After deleting the source GAD pair and the temporary GAD pair, remove the source storage systems if necessary.
The source GAD pair and the temporary GAD pair have been deleted.
- Release the quorum disk settings used for both the source primary and secondary storage systems.
Command example:
raidcom delete quorum -quorum_id 0 -request_id auto -IH0 REQID: 100
Remove the external volumes used for the quorum disks, if necessary.
Note: A maximum of 65,280 request IDs can be assigned to one storage system. If there is no available request ID, the command fails with EX_IDEXHA. If that occurs, see the description of the function of request IDs in the Command Control Interface Command Reference and release request IDs. - Specify the request ID that was displayed in step 1, and check the error information about the CCI configuration command that is performed asynchronously. Verify that the value in the Description column is a hyphen (-).
Command example:
raidcom get command_status -request_id 100 -IH0 REQID R SSB1 SSB2 Serial# ID Description 00000100 - - - 422222 - -
- Confirm that asynchronous command processing has completed, and then release a request ID.
Command example:
raidcom reset command_status -request_id 100 -IH0
- Remove the remote connections used for both the source primary and secondary storage systems.
Command example:
raidcom delete rcu -cu_free 422222 M800 0 -IH0
- Uninstall the GAD licenses used for both the source primary and secondary storage systems.
- Remove the physical paths on the source storage systems, and then remove the storage systems.