Failure on the secondary storage system of the target GAD pair

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04


The following table lists the pair status (in the upper row) and I/O mode (in the lower row) in phases 1 to 6 of a failure occurrence during data migration.

Phase of failure occurrence Volume Source GAD pair Temporary GAD pair created for migration Target GAD pair
Before the failure After the failure Before the failure After the failure Before the failure After the failure
1. Creating a temporary GAD pair for migration P-VOL PAIR

Mirror(RL)

No change COPY

Mirror(RL)

No change
S-VOL PAIR

Mirror(RL)

No change COPY

Block

No change
2. Creating a target GAD pair P-VOL PAIR

Mirror(RL)

No change COPY

Mirror(RL)

No change

COPY

Mirror(RL)

PSUE

Local

S-VOL PAIR

Mirror(RL)

No change COPY

Block

No change

COPY

Block

PSUE

Block

3. Suspending the source GAD pair (at the P-VOL) P-VOL PSUS

Local

No change COPY

Mirror(RL)

No change1

COPY

Mirror(RL)

PSUE

Local

S-VOL SSUS

Block

No change COPY

Block

No change1

COPY

Block

No change
4. The temporary GAD pair is migrated to PAIR P-VOL PSUS

Local

No change PAIR

Mirror(RL)

No change

COPY

Mirror(RL)

PSUE

Local

S-VOL SSUS

Block

No change PAIR

Mirror(RL)

No change

COPY

Block

PSUE

Block

5. Suspending the temporary GAD pair (at the S-VOL) P-VOL PSUS

Local

No change PSUS

Block

No change

COPY

Mirror(RL)

PSUE

Local

S-VOL SSUS

Block

No change SSWS

Local

No change

COPY

Block

PSUE

Block

6. The target GAD pair is migrated to PAIR P-VOL PSUS

Local

No change PSUS

Block

No change

PAIR

Mirror(RL)

PSUE

Local

S-VOL SSUS

Block

No change SSWS

Local

No change

PAIR

Mirror(RL)

PSUE

Block

Notes:
  1. The pair status and the I/O mode might be PAIR(Mirror(RL)) depending on the progress of copy operation.
  2. If there are no update I/Os, the pair status and the I/O mode might remain PAIR(Mirror(RL)).