Recovering from a failure that occurred during phase 1 on the secondary storage system of the source GAD pair

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23
  1. Recover from the failure on the storage system.
  2. Verify that the pair status (I/O mode) of the P-VOL of the source GAD pair is PSUE(Local).
    If the pair status is PAIR(MirrorRL), issue an update I/O, and confirm it is PSUE(Local).

    Command example:

    Pairdisplay –g oraHA00 –fcxe –IH0
    Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
    Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
    QM DM P PR
    oraHA00 dev00(L) (CL1-C-0, 0, 0)411111 1111.P-VOL PSUE
    NEVER , 55 2222 - - 0 1 - - - L/L - D
    N D
    oraHA00 dev00(R) (CL1-C-0, 0, 0)422222 2222.S-VOL PSUE
    NEVER , 100 1111 - - 0 1 - - - B/B - D
    N D
    
  3. Continue data migration using the procedure described in Creating a target GAD pair.