Recovering from a failure (LDEV blockade) that occurred during phase 2 on the S-VOL of the source GAD pair

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

  1. Verify that the pair status (I/O mode) of the P-VOL of the source GAD pair is PSUE(Local).
    Command example:
    Pairdisplay –g oraHA00 –fcxe –IH0
    Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
    Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
    QM DM P PR
    oraHA00 dev00(L) (CL1-C-0, 0, 0)411111 1111.P-VOL PSUE
    NEVER , 55 2222 - - 0 1 - - - L/L - D
    N D
    oraHA00 dev00(R) (CL1-C-0, 0, 0)422222 2222.S-VOL PSUE
    NEVER , 100 1111 - - 0 1 - - - B/B - D
    N D
    
    If the pair status is PAIR(Mirror(RL)), issue an update I/O to the P-VOL of the source GAD pair.
  2. Continue data migration from the procedure described in Suspending the source GAD pair by specifying the P-VOL.