Failure on the primary storage system of the target GAD pair

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04


The following table lists the pair status (in the upper row) and I/O mode (in the lower row) in phases 1 to 6 of a failure occurrence during data migration.

Phase of failure occurrence Volume Source GAD pair Temporary GAD pair created for migration Target GAD pair
Before the failure After the failure Before the failure After the failure Before the failure After the failure
1. Creating a temporary GAD pair P-VOL PAIR Mirror(RL) No change COPY Mirror(RL) PSUE Local    
S-VOL PAIR Mirror(RL) No change COPY Block PSUE Block    
2. Creating a target GAD pair P-VOL PAIR Mirror(RL) No change COPY Mirror(RL) PSUE Local COPY Mirror(RL) PSUE Local
S-VOL PAIR Mirror(RL) No change COPY Block PSUE Block COPY Block No change
3. Suspending the source GAD pair (at the P-VOL) P-VOL PSUS Local No change COPY Mirror(RL) PSUE Local COPY Mirror(RL) PSUE Local
S-VOL SSUS Block No change COPY Block PSUE Block COPY Block No change
4. The temporary GAD pair is migrated to PAIR P-VOL PSUS Local No change PAIR Mirror(RL) PSUE* Local COPY Mirror(RL) PSUE Local
S-VOL SSUS Block No change PAIR Mirror(RL) PSUE Block COPY Block No change
5. Suspending the temporary GAD pair (at the S-VOL) P-VOL PSUS Local No change PSUS Block No change COPY Mirror(RL) PSUE Local
S-VOL SSUS Block No change SSWS Local No change COPY Block No change
6. The target GAD pair is migrated to PAIR P-VOL PSUS Local No change PSUS Block No change PAIR Mirror(RL) PSUE Block
S-VOL SSUS Block No change SSWS Local No change PAIR Mirror(RL) SSWS* Local
*If there are no update I/Os, the pair status and the I/O mode might remain PAIR(Mirror(RL)).