- Recover from the failure on the storage system.
- Delete the source GAD pair and the temporary GAD pair. For details, see Deleting the source GAD pair and the temporary GAD pair for data migration.
-
Resynchronize the target
GAD pair by specifying the S-VOL.
Command example:
pairresync –g oraHA02 –swaps –IH3
-
Verify that the copy operation for the target
GAD pair is complete and the pair status has changed to PAIR.
Command example:
pairdisplay –g oraHA02 –fcxe –IH3 Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S, Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W QM DM P PR oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.P-VOL PAIR NEVER , 100 1111 - - 2 1 - - - L/M - D N D oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.S-VOL PAIR NEVER , 100 2222 - - 2 1 - - - L/M - D N D
-
Reverse the P-VOL and the S-VOL of the target
GAD pair if necessary.
Command example:
pairresync –g oraHA02 –swaps –IH2
-
Verify that the P-VOL and the S-VOL of the target
GAD pair have been reversed.
Command example:
pairdisplay –g oraH02 –fcxe –IH2 Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S, Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W QM DM P PR oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.P-VOL PAIR NEVER , 100 2222 - - 2 1 - - - L/M - D N D oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.S-VOL PAIR NEVER , 100 1111 - - 2 1 - - - L/M - D N D