Recovering from a failure that occurred during phase 6 on the primary storage system of the target GAD pair

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23
  1. Recover from the failure on the storage system.
  2. Delete the source GAD pair and the temporary GAD pair. For details, see Deleting the source GAD pair and the temporary GAD pair for data migration.
  3. Resynchronize the target GAD pair by specifying the S-VOL.
    Command example:
    pairresync –g oraHA02 –swaps –IH3
  4. Verify that the copy operation for the target GAD pair is complete and the pair status has changed to PAIR.
    Command example:
    pairdisplay –g oraHA02 –fcxe –IH3
    Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
    Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
    QM DM P PR
    oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.P-VOL PAIR
    NEVER , 100 1111 - - 2 1 - - - L/M - D
    N D
    oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.S-VOL PAIR
    NEVER , 100 2222 - - 2 1 - - - L/M - D
    N D
    
  5. Reverse the P-VOL and the S-VOL of the target GAD pair if necessary.
    Command example:
    pairresync –g oraHA02 –swaps –IH2
  6. Verify that the P-VOL and the S-VOL of the target GAD pair have been reversed.
    Command example:
    pairdisplay –g oraH02 –fcxe –IH2
    Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
    Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
    QM DM P PR
    oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.P-VOL PAIR
    NEVER , 100 2222 - - 2 1 - - - L/M - D
    N D
    oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.S-VOL PAIR
    NEVER , 100 1111 - - 2 1 - - - L/M - D
    N D