Recovering from a failure that occurred during phase 6 in the remote path from the secondary to the primary storage system of the target GAD pair

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23
  1. Recover from the failure in the remote path.
  2. Verify the pair status of the target GAD pair.
    Command example:
    pairdisplay –g oraHA02 –fcxe –IH2
    Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
    Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
    QM DM P PR
    oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.P-VOL PSUE
    NEVER , 100 2222 - - 2 1 - - - B/B - D
    N D
    oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.S-VOL SSWS
    NEVER , 55 1111 - - 2 1 - - - L/L - D
    N D
    
  3. Perform either of the following recovery procedures depending on the pair status (I/O mode).
    • If the pair status (I/O mode) of the S-VOL of the target GAD pair is SSWS(Local):
      1. Continue data migration using the procedure described in Deleting the source GAD pair and the temporary GAD pair for data migration.
      2. Resynchronize the target GAD pair by specifying the S-VOL.
        Command example:
        pairresync –g oraHA02 -swaps –IH3
      3. Verify that the copy operation for the target GAD pair is complete, and then verify that the pair status has changed to PAIR.
        Command example:
        pairdisplay –g oraH02 –fcxe –IH3
        Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
        Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV#
        R/W QM DM P PR
        oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.P-VOL PAIR
        NEVER , 100 1111 - - 2 1 - - - L/M -
        D N D
        oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.S-VOL PAIR
        NEVER , 100 2222 - - 2 1 - - - L/M -
        D N D
        
    • If the pair status (I/O mode) of the P-VOL of the target GAD pair is PSUE(Local):
      1. Resynchronize the target GAD pair by specifying the P-VOL.
        Command example:
        pairresync –g oraHA02 –IH2
      2. Verify that the copy operation for the target GAD pair is complete, and then verify that the pair status has changed to PAIR.
        Command example:
        pairdisplay –g oraH02 –fcxe –IH2
        Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
        Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV#
        R/W QM DM P PR
        oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.P-VOL PAIR
        NEVER , 100 2222 - - 2 1 - - - L/M -
        D N D
        oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.S-VOL PAIR
        NEVER , 100 1111 - - 2 1 - - - L/M -
        D N D