Recovering from a failure that occurred during phases 5 and 6 in the remote path from the primary to the secondary storage system of the target GAD pair

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

  1. Recover from the failure in the remote path.
  2. Resynchronize the target GAD pair by specifying the P-VOL.
    Command example:
    pairresync –g oraHA02 –IH2
  3. Verify that the copy operation for the target GAD pair is completed and that the pair status has changed to PAIR.
    Command example:
    pairdisplay –g oraHA02 –fcxe –IH2
    Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
    Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
    QM DM P PR
    oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.P-VOL PAIR
    NEVER , 55 2222 - - 2 1 - - - L/M - D
    N D
    oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.S-VOL PAIR
    NEVER ,----- 1111 - - 2 1 - - - B/B - D
    N D
    
  4. Continue data migration from the procedure that you performed before the failure.