  1. Recover from the failure in the remote path.
  2. Resynchronize the target GAD pair by specifying the P-VOL.
    Command example:
    pairresync –g oraHA02 –IH2
  3. Verify that the pair status of the target GAD pair has changed to COPY.
    Command example:
    pairdisplay –g oraHA02 –fcxe –IH2
    Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S,
    Status,Fence,%, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
    QM DM P PR
    oraHA02 dev02(L) (CL1-C-0, 0, 0)833333 1111.P-VOL COPY
    NEVER , 55 2222 - - 2 1 - - - L/M - D
    N D
    oraHA02 dev02(R) (CL1-C-0, 0, 0)844444 2222.S-VOL COPY
    NEVER ,----- 1111 - - 2 1 - - - B/B - D
    N D
    
  4. Continue data migration from the procedure that you performed before the failure.