The following table lists the GAD pair operations that are available when the S-VOL of the GAD pair shares the same volume with the P-VOL of a GAD pair in a dirrerent mirror.

GAD pair operations GAD pair status in a different mirror
INIT/COPY COPY PAIR PSUS PSUE (Local) PSUE (Block)
Create No No No No No No
Split P-VOL specified No Yes Yes Yes Yes Yes
Split S-VOL specified No Yes Yes Yes Yes No
Delete P-VOL specified No No No No No No
Delete S-VOL specified No Yes Yes Yes Yes Yes
Delete forcibly Yes Yes Yes Yes Yes Yes
Resync P-VOL specified No Yes Yes Yes Yes No
Resync S-VOL specified No No No No No No