The following table lists the GAD pair operations that are available when the P-VOL of the GAD pair shares the same volume with the S-VOL of a GAD pair in a different mirror.

GAD pair operations GAD pair status in a different mirror
INIT/COPY COPY PAIR SSUS SSWS PSUE
Create No Yes* Yes* No No No
Split P-VOL specified No Yes Yes Yes Yes Yes
Split S-VOL specified No No No No Yes No
Delete P-VOL specified No Yes Yes Yes Yes Yes
Delete S-VOL specified No No No No No No
Delete forcibly Yes Yes Yes Yes Yes Yes
Resync P-VOL specified No Yes Yes No Yes No
Resync S-VOL specified No No No No No No
*If the nocopy option is specified, the GAD operation is not available.