Changing preferred path settings

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

You can change the asymmetric access status setting required for specifying a preferred path regardless of the GAD pair status, even during I/O processing.

Note: Depending on the operating system of the server to which the storage system is connected, the asymmetric access status settings might not be recognized. If a path is not connected according to the asymmetric access status settings, the operating system of the server might not recognize the asymmetric access status. If this occurs, make the server recognize the device again.

Command example

raidcom modify lun -port CL1-A-0 -lun_id all 
   -asymmetric_access_state non_optimized -IH0