The GAD+UR 3DC delta resync configuration includes the following storage systems:

  • Primary storage system: Contains the P-VOL, UR journal volume (JNL VOL), command device (CMD), and external volume for the quorum disk. The P-VOL and the JNL VOL are virtual volumes of DP and are assigned capacities from different DP pools.
  • GAD secondary storage system: Contains the GAD S-VOL, delta UR journal volume, command device, external volume for the quorum disk, and the virtual storage machine (VSM). The GAD S-VOL must have the same virtual LDEV ID as the P-VOL. Therefore it is registered to the VSM. The GAD secondary storage system must be the same model as the primary storage system.
  • UR secondary storage system: Contains the UR S-VOL, UR/delta UR shared journal volume, command device, and external volume for the quorum disk.
  • External storage system: Contains the GAD quorum disk.
    Note: In this example the quorum disk resides in a separate external storage system. If desired, the quorum disk can reside in the UR secondary storage system.
Primary storage system Secondary storage system
VSP One B85
  • VSP One B85
  • VSP 5000 series (DKCMAIN 90-09-29 or later)
VSP One B26 or VSP One B28
  • VSP One B26
  • VSP One B28
  • VSP E series (DKCMAIN 93-07-23 or later)
  • VSP 5200VSP 5600 (DKCMAIN 90-09-25 or later)