Use the following workflow to recover from a failure on the UR delta resync pair due to a journal volume failure on the storage system at the GAD secondary site that requires replacing the journal volume.
Note: You do not need to delete the UR delta resync pair when you replace journal volumes.
- Set the system option mode 1182 to ON at the GAD secondary storage system.
- Add a reserve journal volume.
After a reserve journal volume is added, the UR delta resync pair status changes to PSUE, and the SIM code dc9xxx or 7ff103 is issued.
If a reserve journal volume has already been added, delete the reserve journal volume from the journal, and then add a reserve journal volume again.
- Delete the journal volume in which a failure occurred, from the journal.
- Resynchronize the UR
delta resync pair to restore its status from the failure.
Command example:
pairresync -g oraDELTA -hold y
- Confirm that the status of the P-VOL of the UR delta resync pair is PSUS.
If the server has stopped I/Os, the status is PSUE.
Command example:
pairdisplay -g oraDELTA -fxce -IH1 Group PairVol(L/R) (Port#,TID, LU),Seq#, LDEV#.P/S, Status,Fence, %, P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W oraDELTA dev3(L) (CL1-A-1, 0, 1) 822222 4444. P-VOL PSUS ASYNC ,0 6666 - 0 0 - - - - -/- oraDELTA dev3(R) (CL1-A-1, 0, 1) 844444 6666. S-VOL SSUS ASYNC ,0 4444 - 0 0 - - - - -/-
- Confirm that the mirror status of the journal of the UR delta resync pair is PJNS.
Command example:
pairdisplay -g oraDELTA -v jnl -IH1 JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# Num LDEV# 000 1 1 PJNS 4 21 43216fde 30 512345 62500 1 39321
- Set the system option mode 1182 to OFF at the GAD secondary storage system.
- Confirm that no failure SIMs are displayed.