If a virtual LDEV ID value is not correct, you can set the correct value.
If the DKCMAIN microcode version is A0-05-41 or later, check whether VSM auto-configuration is used on the operation-target volume beforehand. If AUTO_VIRTUAL_STORAGE is YES, VSM auto-configuration is used. If AUTO_VIRTUAL_STORAGE is NO, VSM auto-configuration is not used.
If the DKCMAIN microcode version is earlier than A0-05-41, perform the procedure of VSM manual configuration.
Command example
raidcom get ldev –ldev_id 0x1111 –key virtual –fx –IH100 LDEV# VIR_LDEV Serial# V_Serial# V_ID V_NUMBER VOL_TYPE VIR_VOL_TYPE SSID VIR_SSID AUTO_VIRTUAL_STORAGE 1111 2222 900061 911111 RH20ETP 1 OPEN-V-CVS OPEN-V-CVS a a YES