Setting correct virtual LDEV ID values when VSM auto-configuration is used

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23
  1. Reset the virtual information.
    raidcom modify ldev -ldev_id 0x1111 -virtual_info reset
  2. Check the virtual LDEV ID.
    raidcom get ldev –ldev_id 0x1111 –key virtual –fx –IH100
    LDEV# VIR_LDEV Serial# V_Serial# V_ID V_NUMBER VOL_TYPE
    VIR_VOL_TYPE SSID VIR_SSID AUTO_VIRTUAL_STORAGE
    1111 1111 900061 900061 RH20ETP 1 OPEN-V-CVS
    - a – NO
    
  3. If you set a virtual storage machine as a P-VOL, perform the procedure of VSM manual configuration in Setting up the secondary storage system, in which replace the S-VOL with the P-VOL when you perform the procedure.

    If you set the virtual LDEV ID that is the same as the actual LDEV ID, perform the procedure in Setting the GAD reserve attribute on the S-VOL (VSM manual configuration), in which set the actual LDEV ID instead of assigning the GAD reserve attribute.

    If you set a virtual storage machine as an S-VOL, you set the virtual serial number, virtual model, and virtual LDEV ID that are the same as the ones for the P-VOL. In this case, perform the procedure of VSM manual configuration in Setting up the secondary storage system.

    In the procedure in Setting the GAD reserve attribute on the S-VOL (VSM manual configuration), set the virtual LDEV ID of the P-VOL instead of assigning the GAD reserve attribute.