Pair condition before failure

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

The pair status and I/O mode of a GAD pair, the accessibility of the server, and the storage location of the latest data depend on the status before a failure occurs.

The following table shows pair status and I/O mode, the volumes accessible from the server, and the location of the latest data before a failure occurs. You can compare this information with the changes that take place after a failure occurs, as described in the following topics.

Pair status and I/O mode

Volume accessible from the server

Volume with latest data

P-VOL

S-VOL

P-VOL

S-VOL

PAIR (Mirror (RL))

PAIR (Mirror (RL))

OK

OK

Both P-VOL and S-VOL

PAIR (Mirror (RL))

PAIR (Block)

OK

NG

Both P-VOL and S-VOL

COPY (Mirror (RL))

COPY (Block)

OK

NG

P-VOL

PSUS/PSUE (Local)

SSUS/PSUE (Block)

OK

NG

P-VOL

PSUS/PSUE (Block)

SSWS (Local)

NG

OK

S-VOL