When the secondary storage system fails, you can correct the issue by recovering the secondary storage system, recovering the physical path between primary and secondary storage systems, and recovering the pair.
GAD pairs might be created between the primary and secondary sites that configure GAD as follows:
- A P-VOL of a GAD pair is at site 1 and a S-VOL is at site 2.
- A P-VOL of a different GAD pair is at site 2 and a S-VOL is at site 1.
In this case, recover from a failure at the primary storage system. For more information, see Pair condition and recovery: primary storage system failure.
The following table shows transitions for pair status and I/O mode, the volumes accessible from the server, and location of the latest data when you can no longer use the secondary storage system due to failure.
|
Before failure |
After failure |
|||||
|---|---|---|---|---|---|---|
|
Pair status and I/O mode |
Pair status and I/O mode |
Volume accessible from the server |
Volume with latest data |
|||
|
P-VOL |
S-VOL |
P-VOL |
S-VOL1 |
P-VOL |
S-VOL |
|
|
PAIR (Mirror (RL)) |
PAIR (Mirror (RL)) |
PSUE (Local)2 |
PSUE (Block) |
OK |
NG |
P-VOL |
|
PAIR (Mirror (RL)) |
PAIR (Block) |
PSUE (Local) |
PSUE (Block) |
OK |
NG |
P-VOL |
|
COPY (Mirror (RL)) |
COPY (Block) |
PSUE (Local) |
PSUE (Block) |
OK |
NG |
P-VOL |
|
PSUS/PSUE (Local) |
SSUS/PSUE (Block) |
PSUS/PSUE (Local) |
SSUS/PSUE (Block) |
OK |
NG |
P-VOL |
|
PSUS/PSUE (Block) |
SSWS (Local) |
PSUS/PSUE (Block) |
SSWS (Local) |
NG |
NG |
S-VOL |
|
Notes:
|
||||||
SIMs
- Primary storage system: 2180xx, DD0xyy, DD3xyy
- Secondary storage system: SIM varies depending on the failure type