Pair condition and recovery: quorum disk failure

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

GAD pairs might be created between the primary and secondary sites that configure GAD as follows:

  • A P-VOL of a GAD pair is at site 1 and a S-VOL is at site 2.
  • A P-VOL of a different GAD pair is at site 2 and a S-VOL is at site 1.

In this case, recover from a physical path failure.

The following table shows transitions for pair status and I/O mode, the volumes that are accessible from the server, and the location of the latest data when you can no longer use the quorum disk volume.

Before failure

After failure

Pair status and I/O mode

Pair status and I/O mode

Volume accessible from the server

Volume with latest data

P-VOL

S-VOL

P-VOL

S-VOL

P-VOL

S-VOL

PAIR (Mirror(RL))

PAIR (Mirror(RL))

PAIR (Mirror(RL))

PAIR (Mirror(RL))

OK

OK

Both P-VOL and S-VOL

PAIR (Mirror (RL))

PAIR (Block)

PAIR (Mirror(RL))

PAIR (Block)

OK

NG

Both P-VOL and S-VOL

COPY (Mirror(RL))

COPY (Block)

COPY (Mirror(RL))*

COPY (Block)*

OK

NG

P-VOL

PSUS/PSUE (Local)

SSUS/PSUE (Block)

PSUS/PSUE (Local)

SSUS/PSUE (Block)

OK

NG

P-VOL

PSUS/PSUE (Block)

SSWS (Local)

PSUS/PSUE (Block)

SSWS (Local)

NG

OK

S-VOL

The P-VOL might change to PSUE (Local) and the S-VOL might change to PSUE (Block) if a quorum disk failure occurred immediately after the pair status changed to COPY.

SIMs

  • Primary storage system: 21D0xy, 21D2xx, DD2xyy, DEF0zz, EF5xyy, EFD000, FF5xyy
  • Secondary storage system: 21D0xy, 21D2xx, DD2xyy, DEF0zz, EF5xyy, EFD000, FF5xyy
  1. Recover the quorum disk.
  2. Resynchronize or re-create GAD pairs if they are suspended by a failure.
    If a failure occurs after the one volume capacity of a GAD pair can be expanded, the creation, resync, swap resync, and horctakeover operations of the GAD pair cannot be performed because the capacity of both the volumes is not the same. Make sure to expand the other volume capacity so that the capacity of both the volumes is the same, and then retry the operation.