When the GAD status of the pair changes to Suspended, the P-VOL I/O mode changes to Local and the S-VOL I/O mode changes to Block. Server I/O continues on the P-VOL.
- (VSP One B20 series) When the GAD status of the pair changes to Quorum disk blocked, the P-VOL I/O mode remains Mirror (RL), and the S-VOL I/O mode changes to Block.
- (VSP One B85) When the GAD status of the pair changes to Quorum disk blocked, the P-VOL and S-VOL I/O modes remain Mirror (RL).
Server I/O continues on the P-VOL.
The following figure shows the failure area and recovery when a pair is suspended due to quorum disk failure.
Confirming the CVS attribute on the external storage system
|
Interface |
To confirm the CVS attribute: |
|---|---|
|
CCI |
Execute the raidcom get ldev command from CCI to the LDEV which is used as quorum disk by external storage system, and then confirm whether the CVS attribute is output for VOL_TYPE. Details of the raidcom get ldev command; refer to Command Control Interface Command Reference. |
|
Web Console* |
Confirm whether the CVS attribute is displayed in the CVS column on the LUN Management window. |
|
* Ask the maintenance personnel to operate the Web Console. |
|
Conditions for the CVS attribute for volumes created in the external storage system
|
Interface |
Condition |
CVS attribute |
||
|---|---|---|---|---|
|
CCI |
Internal volume or external volume |
Allowed |
||
|
DP-VOL |
VSP 5000 series, VSP G1x00, VSP F1500 |
Allowed |
||
|
VSP or earlier |
Create LDEV of maximum size |
Not allowed |
||
|
Create LDEV less than maximum size |
Allowed |
|||
|
Web Console* |
The LDEV is created during the operation of Define Config & Install or the installation of ECC/LDEV, with the initial value of the Number of LDEVs on the Device Emulation Type Define window. |
Not allowed |
||
|
Other than above |
Allowed |
|||
|
* Ask the maintenance personnel to use the Web Console. |
||||