When a failure occurs on the path between the secondary storage system and the external storage system, you should know how to resolve the failure and restore the GAD pair. The following figure shows the failure area and recovery when the GAD status of a pair changes to Suspended or Quorum disk blocked due to path failure from the secondary storage system to the external storage system.
When the GAD status of the pair changes to Suspended, the P-VOL I/O mode changes to Local and the S-VOL I/O mode changes to Block. Server I/O continues on the P-VOL.
- (VSP One Block 20 series) When the GAD status of the pair changes to Quorum disk blocked, the P-VOL I/O mode remains Mirror (RL), and the S-VOL I/O mode changes to Block.
- (VSP One B85) When the GAD status of the pair changes to Quorum disk blocked, the P-VOL and S-VOL I/O modes remain Mirror (RL).
Server I/O continues on the P-VOL.