If the statuses of storage systems in both the primary and secondary sites are normal, a failure might have occurred in a physical path or switch between the storage systems. You can correct the issue by recovering the paths and resynchronizing the pair.
GAD pairs might be created between the primary and secondary sites that configure GAD as follows:
- A P-VOL of a GAD pair is at site 1 and a S-VOL is at site 2.
- A P-VOL of a different GAD pair is at site 2 and a S-VOL is at site 1.
In this case, recover from a physical path failure at the secondary site. For more information, see Pair condition and recovery: path failure, secondary to primary storage system.
The following table shows transitions for pair status and I/O mode, the volumes that are accessible from the server, and the location of the latest data when you can no longer use any physical path from the primary storage system to the secondary storage system.
|
Before failure |
After failure |
|||||
|---|---|---|---|---|---|---|
|
Pair status and I/O mode |
Pair status and I/O mode |
Volume accessible from the server |
Volume with latest data |
|||
|
P-VOL |
S-VOL |
P-VOL |
S-VOL |
P-VOL |
S-VOL |
|
|
PAIR (Mirror(RL))1 |
PAIR (Mirror(RL))1 |
PSUE (Local) |
PSUE (Block) |
OK |
NG |
P-VOL |
|
PAIR (Mirror(RL)) |
PAIR (Block) |
PSUE (Local) |
PAIR (Block) |
OK |
NG |
P-VOL |
|
COPY (Mirror(RL)) |
COPY (Block) |
PSUE (Local) |
PSUE/COPY (Block)2 |
OK |
NG |
P-VOL |
|
PSUS/PSUE (Local) |
SSUS/PSUE (Block) |
PSUS/PSUE (Local) |
SSUS/PSUE (Block) |
OK |
NG |
P-VOL |
|
PSUS/PSUE (Block) |
SSWS (Local) |
PSUS/PSUE (Block) |
SSWS (Local) |
NG |
OK |
S-VOL |
|
Notes:
|
||||||
SIMs
- Primary storage system: DD0xyy, 2180xx
- Secondary storage system: DD3xyy