Pair condition and recovery: path failure, primary to external storage system

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04

If the status of the external storage system is normal, a failure might have occurred in a physical path from the primary or secondary storage system to the external storage system, or a switch. Recover from the failure that occurred in the physical path or switch.

The following table shows transitions for pair status and I/O mode, the volumes that are accessible from the server, and the location of the latest data when you can no longer use any physical path from the primary storage system to the quorum disk's external storage system.

GAD pairs might be created between the primary and secondary sites that configure GAD as follows:

  • A P-VOL of a GAD pair is at site 1 and a S-VOL is at site 2.
  • A P-VOL of a different GAD pair is at site 2 and a S-VOL is at site 1.

In this case, recover from a physical path failure at the secondary site. For more information, see Pair condition and recovery: path failure, secondary to external storage system.

Before failure

After failure

Pair status and I/O mode

Pair status and I/O mode

Volume accessible from the server

Volume with latest data

P-VOL

S-VOL

P-VOL

S-VOL

P-VOL

S-VOL

PAIR (Mirror(RL))

PAIR (Mirror(RL))

PAIR (Mirror(RL))

PAIR (Mirror(RL))

OK

OK

Both P-VOL and S-VOL

PAIR (Mirror (RL))

PAIR (Block)

PAIR (Mirror (RL))

PAIR (Block)

OK

NG

Both P-VOL and S-VOL

COPY (Mirror(RL))

COPY (Block)

COPY (Mirror(RL))*

COPY (Block)*

OK

NG

P-VOL

PSUS/PSUE (Local)

SSUS/PSUE (Block)

PSUS/PSUE (Local)

SSUS/PSUE (Block)

OK

NG

P-VOL

PSUS/PSUE (Block)

SSWS (Local)

PSUS/PSUE (Block)

SSWS (Local)

NG

OK

S-VOL

* The P-VOL might change to PSUE (Local) and the S-VOL might change to PSUE (Block) if a failure occurred on a physical path to an external storage system for quorum disks immediately after the pair status changed to COPY.

SIMs

  • Primary storage system: 21D0xy, 21D2xx, DD2xyy, DEF0zz, EF5xyy, EFD000, FF5xyy
  • Secondary storage system: DD2xyy
  1. Recover the paths to the external storage system.
  2. Resynchronize the pair suspended by a failure.
    If a failure occurs after the one volume capacity of a GAD pair can be expanded, the creation, resync, swap resync, and horctakeover operations of the GAD pair cannot be performed because the capacity of both the volumes is not the same. Make sure to expand the other volume capacity so that the capacity of both the volumes is the same, and then retry the operation.