Generally, you can correct failures by recovering the paths and resynchronizing the pair. The following table shows transitions for pair status and I/O mode, the volumes that are accessible from the server, and the location of the latest data when a failure other than explained above occurs.
|
Before failure |
After failure |
|||||
|---|---|---|---|---|---|---|
|
Pair status and I/O mode |
Pair status and I/O mode |
Volume accessible from the server |
Volume with latest data |
|||
|
P-VOL |
S-VOL |
P-VOL |
S-VOL |
P-VOL |
S-VOL |
|
|
PAIR (Mirror (RL))1 |
PAIR (Mirror (RL))1 |
PSUE (Local) |
PSUE (Block) |
OK |
NG |
P-VOL |
|
PSUE (Block) |
SSWS (Local) |
NG |
OK |
S-VOL |
||
|
PAIR (Mirror (RL)) |
PAIR (Block) |
OK |
NG |
Both P-VOL and S-VOL |
||
|
PAIR (Mirror (RL)) |
PAIR (Block) |
PSUE (Block) |
SSWS (Local) |
NG |
OK |
S-VOL |
|
COPY (Mirror (RL)) |
COPY (Block) |
PSUE (Local) |
PSUE/COPY (Block) |
OK |
NG |
P-VOL |
|
NG2 |
NG |
P-VOL |
||||
|
PSUS/PSUE (Local) |
SSUS/PSUE (Block) |
PSUS/PSUE (Local) |
SSUS/PSUE (Block) |
OK |
NG |
P-VOL |
|
NG2 |
NG |
P-VOL |
||||
|
PSUS/PSUE (Block) |
SSWS (Local) |
PSUS/PSUE (Block) |
SSWS (Local) |
NG |
OK |
S-VOL |
|
NG |
NG3 |
S-VOL |
||||
|
Notes:
|
||||||
SIMs
- Primary storage system: SIM varies depending on the failure type
- Secondary storage system: SIM varies depending on the failure type