Failure locations

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04

The following figure and table describe the locations where GAD failures can occur, the SIMs that are issued, and whether the P-VOL and S-VOL are accessible. All GAD-related SIMs are described in SIMs related to GAD.

Figure. Failure locations

#

Failure location

SIM reference codes

GAD volume accessible?1

Primary storage system

Secondary storage system

P-VOL

S-VOL

1

Server

None (normal)

None (normal)

Yes

Yes

2

Path between the server and the storage system

Path between the server and the primary storage system

None (normal)

None (normal)

No

Yes2

3

Path between the server and the secondary storage system

None (normal)

None (normal)

Yes3

No

4

GAD pair volume

P-VOL

3A0xxx

DB8xxx

DB9xxx

DBAxxx

DBBxxx

DD1xyy

DFAxxx

DFBxxx

EF8xxx

EF9xxx

DD1xyy

No

Yes2

5

S-VOL

DD1xyy

3A0xxx

DB8xxx

DB9xxx

DBAxxx

DBBxxx

DD1xyy

DFAxxx

DFBxxx

EF8xxx

EF9xxx

Yes3

No

6

Pool for GAD pair4

Pool for P-VOL

622xxx

62axxx

DD1xyy

DD1xyy

No

Yes2

7

Pool for S-VOL

DD1xyy

622xxx

62axxx

DD1xyy

Yes3

No

8

Path between storage systems

Remote path from the primary to secondary storage system

2180xx

DD0xyy

DD3xyy

Yes3

No

9

Remote path from the secondary to primary storage system

DD3xyy

2180xx

DD0xyy

No

Yes2

10

Storage system

Primary storage system

Depends on the failure type5

2180xx

DD0xyy

DD3xyy

No

Yes2

11

Secondary storage system

2180xx

DD0xyy

DD3xyy

Depends on the failure type5

Yes3

No

12

Quorum disk

Path between the primary storage system and quorum disk

21D0xx

21D2xx

DD2xyy

DEF0zz

EF5xyy

EFD000

FF5xyy

DD2xyy

Yes3

Yes2

13

Path between the secondary storage system and quorum disk

DD2xyy

21D0xx

21D2xx

DD2xyy

DEF0zz

EF5xyy

EFD000

FF5xyy

Yes3

Yes2

14

Quorum disk

21D0xx

21D2xx

DD2xyy

DEF0zz

EF5xyy

EFD000

FF5xyy

21D0xx

21D2xx

DD2xyy

DEF0zz

EF5xyy

EFD000

FF5xyy

Yes3

Yes2

15

External storage system

21D0xx

21D2xx

DD2xyy

DEF0zz

EF5xyy

EFD000

FF5xyy

21D0xx

21D2xx

DD2xyy

DEF0zz

EF5xyy

EFD000

FF5xyy

Yes3

Yes2

Notes:

  1. Pairs are not suspended and do not become inaccessible for:
    • Failure in hardware used for redundancy in the storage system, such as drives, cache, channel board (CHB), disk board (DKB), and MPU
    • Failure in redundant physical paths
  2. The volume is not accessible if a failure occurs while the S-VOL pair status is COPY, SSUS, or PSUE, and the I/O mode is BLOCK. The volume is accessible if a failure occurs while the S-VOL pair status is PAIR, or SSWS.
  3. The volume is not accessible if a failure occurs while the P-VOL pair status is PSUS or PSUE and the I/O mode is BLOCK. The volume is accessible if a failure occurs while the P-VOL pair status is PAIR, PSUS, or PSUE, and the I/O mode is Mirror (RL) or Local.
  4. A failure occurs due to a full pool for a GAD pair.
  5. The SIM might not be viewable, depending on the failure (for example, all cache failure, all MP failure, storage system failure).