The secondary storage system components used in the procedures and examples in this chapter have the following settings.

Secondary storage system

Model

Serial number

VSP One Block 28

822222

Secondary volume

Actual LDEV ID

Pool ID

Capacity

Port name

LU number

44:44

0

1,024,000 blocks

CL1-C

0

Ports for remote connections

  • CL3-C
  • CL4-C

External volume for the quorum disk

Actual LDEV ID

Port name

External volume group number

Path group ID

LU number

Quorum disk ID

88:88

CL5-C

1-2

1

0

0

Resource group (for VSM manual configuration only)

Resource group name

Virtual storage machine

Model

Serial number

HAGroup1

VSP One B28

811111

Host group

Host group ID

Host group name

Usage

CL1-C-0

1C-G00

For the S-VOL

Pool

Pool ID

Pool name

Pool volume

Usage

LDEV ID

Parity group

Capacity

0

HA_POOL

Automatically assigned

13-4

Automatically assigned

For the GAD S-VOL

Pair

Pair type

Pair group name

Device name (LDEV ID)

Mirror ID

CTG ID

GAD

oraHA

dev1(44:44)

0

2