You must create a command device (CMD) on each storage system for communication between CCI and the storage systems. The command devices must be created in resource group 0 in the primary storage system and secondary storage system. After the command devices have been created, host recognition must be set to the command devices. You can create a command device using a volume with an LU path defined via the SCSI host interface. You can also create a command device using a volume defined as a namespace via the NVMe-oF host interface.
The following figure shows the CCI command devices in a typical GAD configuration. You can use CCI to create the command devices.
Workflow for creating CCI command devices
- Allocate a command device in Resource Group 0 in both storage systems and enable user authentication.
- If necessary, change the topology and fabric settings for the ports defined to the command devices.
- Define the volume to the port connected to the host.