Using raidcom commands to resynchronize a GAD pair

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

This section describes how to resynchronize the following pair (pair status: PSUS or PSUE):

  • LDEV ID of the P-VOL: 0x2222
  • Mirror ID: 0
Run the command for resynchronizing a pair.

Run the command on the primary storage system.

  • Resynchronizing the target pair only:
    raidcom modify remote_copy_pair -ldev_id 0x2222 -mirror_id 0
    -operation resync
    
  • Resynchronizing, in a batch, all pairs in the consistency group to which the target pair belongs:
    raidcom modify remote_copy_pair -ldev_id 0x2222 -mirror_id 0
    -operation resync -range_group