Using raidcom commands to change the GAD pair status to SSWS

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04

Caution: After you change the GAD pair status to SSWS, the P-VOL will not be accessible from the server.

This section describes how to change the status of the following pair (pair status: PAIR) to SSWS:

  • LDEV ID of the S-VOL: 0x4444
  • Mirror ID: 0
Run the command for changing the pair status to SSWS.

Run the command on the secondary storage system.

  • Changing the status of the target pair only:
    raidcom modify remote_copy_pair -ldev_id 0x4444 -mirror_id 0
    -operation swap_split
    
  • Changing the pair status in a batch, of all pairs in the consistency group to which the target pair belongs:
    raidcom modify remote_copy_pair -ldev_id 0x4444 -mirror_id 0
    -operation swap_split -range_group