Parameter range for CCI options

Global Active Device for VSP One Block

Version
10.5.x
File Size
25537 KB
Audience
anonymous
Part Number
MK-23VSP1B011-11
ft:lastEdition
2026-06-23

The following table shows the range of parameters that can be set for CCI options. For details about CCI commands, see the Command Control Interface Command Reference.

Parameter

Range

Mirror ID (MU#)

0 to 3

CTG ID

VSP One B26, VSP One B28: 0 to 127*

VSP One B85: 0 to 1023

* VSP One B24 does not support consistency groups.

Quorum ID

0 to 31

Path group ID

0 to 255

Maximum number of initial copy volumes

1 to 512

Blocked Path Monitoring time

2 to 200 seconds1, 3

Blocked Path SIM Monitoring time

2 to 200 seconds2, 3

Read Response Guaranteed Time When Quorum Monitoring Stopped

5 to 100 seconds

Notes:
  1. The range is 2 to 45 seconds when the DKCMAIN firmware version is less than A3-04-21-xx/xx.
  2. The range is 2 to 100 seconds when the DKCMAIN firmware version is less than A3-04-21-xx/xx.
  3. (VSP One B20 series) The same value is used for TrueCopy, Universal Replicator, and global-active device.