You can modify the storage port settings.

  • Identify the following:
    • Port ID
    • Port security
    • Port speed
    • FC, iSCSI, or NVMe/TCP information

      For details on the combination of port speed and FC-related information, see the Provisioning Guide.

  • Make sure that the user performing the procedure has been assigned the Storage Administrator (Provisioning) role.
  1. From the navigation tree, select Storage > Ports.
  2. From the inventory of ports, select the checkbox for the target port, and then click Edit Port in the action bar.
  3. Check and modify the settings.
    Note:
    • For a channel board (10 Gbps, iSCSI (optical)) port, set 10 Gbps for Port Speed. If you specify a different value, it will be ignored.
    • For a channel board (25Gbps iSCSI (Optical)) port, do not specify the IPv6 DEFAULT GATEWAY if you are using a gateway address that uses Route Advertisement (RA).

      If there are multiple IPv6 gateway addresses in the same network, performance delays might occur.

  4. Click the port ID to open the details page, and then verify that the settings are correctly specified.