Shock and vibration

Installing an HCP RAIN System - Final On-Site Setup

Version
9.7.x
File Size
35463 KB
Audience
anonymous
Part Number
MK-98ARC016-35

The table below shows the tested limits for shock and vibration for an HCP system and its components where this information is available.

Component Operating shock Non-operating shock Operating vibration Non-operating vibration
HCP system (not including storage components) 20G, 6ms, half-sine 33G, 11ms, half-sine, 3/eg axis 0.2Grms on z axis, 2 minutes 1.87Grms on 3 axes, 30 minutes
HCP G11 Node 31G, 2.6ms, ±5%, shock pulse 20in/sec or 51cm/sec, bottom side 71G (2ms) ±5%, shock pulse 35in/sec or 89cm/sec, 6 sides 0.2Grms on z axis, 2 minutes 1.87Grms on 3 axes, 30 minutes
Brocade ICX 6430 IEC 68-2-36, IEC 68-2-6
HP 4208VL N/A N/A N/A N/A
Brocade VDX 6740 20G, 11ms, half-sine 44G, 15ms, square wave 0.5G peak, 0.7Grms random, 5 to 500 Hz 2.0G sine, 1.4Grms random, 5 to 500 Hz
Cisco Nexus 5548 N/A N/A N/A N/A
Cisco Nexus 5596 N/A N/A N/A N/A