  1. Using a #2 Phillips screwdriver, attach the L shaped mounting brackets to the sides of the device using four flat-head screws provided in the kit.


  2. Insert four caged nuts in the top and bottom square holes on the left and right sides of the rear of the rack in position U27.
  3. Using a #2 Phillips screwdriver, mount the device in a two-post rack using four rack-mounting screws for each switch.


  4. Repeat steps 1 through 3 to install the other Brocade ICX 6430 switch into rack position U28.
  5. Install two venting panels in the front of the rack in positions U27 and U28.
    1. Insert a single caged nut in the center square hole of the left and right side of the rack at positions U27 and U28.
    2. Use rack mounting screws to secure the perforated blanking panels to the front of the rack.